OTR-1901 Oxygen Permeability Tester

OTR-1901 Oxygen Permeability Tester

OTR-1901 Oxygen Permeability Tester

Application

OTR-1901 is based on the coulometric sensor method and available for the OTR test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results.

Films:

Plastic films, aluminum foil, aluminized films, plastic composite films, paper-plastic composite films, coextruded films, aluminum foil composite films and many others.

Packages:

Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. red wine bottles, blister packs, various plastic bottles, Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, cosmetic packages, soft tubes for toothpaste, jelly and yogurt cups.

Features

  • Coulometric sensor method
  • Own technology
  • Film and package test
  • 3 specimens test simultaneously and independently
  • One-button test, fully automatic process
  • Multiple test modes optional
  • Data curves display
  • Computer control
  • Digital flow adjustment
  • 3 embedded chamber temperature sensors
  • Environment temperature and humidity sensor inside
  • Chamber water bath technology
  • Unit based on embedded system, 24bit Δ-Σ AD
  • Pressure, oxygen and temperature overload protection
  • Traceable reference film calibration
  • Supports DSM system (DSM, lab data management system)

Principles

Film:

The specimen is clamped between the upper and lower chambers. The upper chamber is purged with an oxygen stream while the lower chamber is purged with a nitrogen stream. Due to the oxygen concentration gradient, oxygen molecules permeate through the specimen and are carried to a coulometric sensor, which generates a proportional signal from which the oxygen transmission rate and permeability coefficient are calculated.

Package:

The package is mounted on the lower chamber with the outside exposed to air or a pure oxygen stream and the inside purged by a nitrogen stream. Oxygen permeates through the package wall, and the penetrated molecules are carried to the coulometric sensor to determine the oxygen transmission rate.

Technical Indexes

  • Test Range:
  • Film: 0.01-6500 cm³/m²·d (Standard)
  • Film: 0.07-65,000 cm³/m²·d (Optional)
  • Resolution (Film): 0.001 cm³/m²·d
  • Package: 0.0001–62 cm³/pkg·d
  • Resolution (Package): 0.00001 cm³/pkg·d
  • Specimen Capacity: 3 specimens, independent
  • Temperature Range: 5°C – 95°C (Accuracy: ±0.1°C)
  • Humidity Range: 0%RH, 35%RH–90%RH, 100%RH (Accuracy: ±1%RH)
  • Test Area: 50 cm²
  • Specimen Size:
    Film: ≥150mm × 94mm; thickness < 1mm
    Package: max size D120mm × 400mm
  • Carrier Gas: 99.999% Nitrogen
  • Carrier Flow: 0–20 ml/min
  • Gas Interface: 1/8 inch
  • Power Supply: AC 220V, 50Hz

Standards

  • ASTM D3985
  • ASTM F2622
  • ASTM F1307
  • ASTM F1927
  • ISO 15105-2
  • GB/T 19789
  • JIS K7126-B
  • YBB 00082003

Configuration

Delivery: Main unit, computer, OX-TRANS software, temperature controller, tank regulator, PCIE card, communication cable, sample cutter, vacuum grease.

Optional: Package fixtures, reference film, vacuum grease, sample cutter, DSM system.

Note: Specifications are subject to change without prior notice.